Hard starts, sticking and a sputtering arc – why low-hydrogen electrodes need the right machine, and what to use instead.
A common complaint: "E7018 doesn't run well – it keeps sticking." Often the electrode is fine. The problem is the machine.
What's going on
Low-hydrogen electrodes like E7018 and E7016 have a basic (lime-fluoride) coating. It gives tough, crack-resistant welds, but it is harder to ionise than the rutile coating on E6013. To strike and keep the arc going on AC, the machine needs enough open-circuit voltage (OCV) – roughly 70 V or more.
Many small, low-cost transformers in Indian workshops give 45–60 V OCV. That is plenty for E6013 but not for E7018 on AC.
Signs your machine is the problem
- The electrode sticks again and again at the start
- The arc goes out when you lengthen it slightly
- A sputtering, unstable arc even at the right current
What to do
- Use a DC machine or inverter – E7018 runs best on DC+.
- Use E7016 – made to run more easily on AC, with the same low-hydrogen benefits (still needs a good AC machine).
- Keep electrodes dry – damp low-hydrogen electrodes are harder to strike. Re-dry at 300–350 °C for 1 hour.
- For general work on a small transformer, use E6013 – that is what it is designed for.