Knowledge Centre
Everything about covered welding electrodes – types and uses, current settings, how to weld, storage and fixing common defects.
Which Electrode Does What?
Tap a type to see its coating, current, positions, uses and a practical tip.
E6013RutileGeneral purpose – mild steelMentrode – in production
E7016Basic low hydrogenCrack-resistant weldsMentrode – in production
E7018Basic low hydrogen · iron powderHigh strength, smooth beadMentrode – in production
E6010 / E6011CellulosicDeep penetration, pipe rootMade to order / coming
E7024Rutile · iron powderHigh depositionMade to order / coming
E8018-G / E9018-G / E10018-GLow alloy · low hydrogenHigh-strength steelsMade to order / coming
E7018-1Low hydrogen · low temperatureImpact toughness at −46 °CMade to order / coming
SS 308L / 309L / 316LStainless steelCorrosion resistantMade to order / coming
Cast ironNickel / steel typesRepair & joiningMade to order / coming
HardfacingWear resistant30 to 64 HRCMade to order / coming
Cutting & gougingSpecial purposeNo gas or air neededMade to order / coming
What Does E7018 Mean?
Every AWS A5.1 electrode code tells you its strength, positions and coating. Indian IS 814 codes describe the same electrode in a different format.
| Last digits | Coating | Current |
|---|---|---|
| E••10 | Cellulose, sodium | DC+ |
| E••11 | Cellulose, potassium | AC, DC+ |
| E••12 | Rutile, sodium | AC, DC− |
| E••13 | Rutile, potassium | AC, DC± |
| E••14 | Rutile, iron powder | AC, DC± |
| E••15 | Low hydrogen, sodium | DC+ |
| E••16 | Low hydrogen, potassium | AC, DC+ |
| E••18 | Low hydrogen, potassium, iron powder | AC, DC+ |
| E••24 | Rutile, iron powder (flat/horizontal) | AC, DC± |
| E••28 | Low hydrogen, iron powder (flat/horizontal) | AC, DC+ |
AWS and IS 814 Side by Side
| AWS A5.1 | IS 814 |
|---|---|
| E6013 | ER4211 |
| E7016 | EB5426H3X |
| E7018 | EB5426H3JX |
In IS 814: E = covered electrode, R/B = rutile/basic coating, the next digits give strength and impact class, H3 = low hydrogen, J = iron powder (high recovery), X = radiographic quality.
The Strength Number – E60, E70, E80 and Up
The first two digits (three from E100 up) give the minimum tensile strength of the weld metal in thousands of psi (ksi). E60 and E70 electrodes are covered by AWS A5.1 (carbon steel); E80 and above are low-alloy electrodes under AWS A5.5 and always carry a suffix that shows the alloy.
| Code | Min. tensile | Metric (A5.1M / A5.5M) | Standard | Typical electrodes |
|---|---|---|---|---|
| E60xx | 60 ksi · 430 MPa | E43xx | AWS A5.1 | E6010, E6011, E6013 |
| E70xx | 70 ksi · 490 MPa | E49xx | AWS A5.1 | E7016, E7018, E7024 |
| E80xx | 80 ksi · 550 MPa | E55xx | AWS A5.5 | E8018-B2, E8018-C1, E8010-P1 |
| E90xx | 90 ksi · 620 MPa | E62xx | AWS A5.5 | E9018-B3, E9018-G |
| E100xx | 100 ksi · 690 MPa | E69xx | AWS A5.5 | E10018-G, E10018-M |
| E110xx | 110 ksi · 760 MPa | E76xx | AWS A5.5 | E11018-G, E11018-M |
| E120xx | 120 ksi · 830 MPa | E83xx | AWS A5.5 | E12018-M |
Higher strength is not always better: match the electrode to the strength of the steel you are welding. Over-matching hard, high-strength weld metal on mild steel can increase the risk of cracking.
What Comes After the Dash
Letters and numbers after the main code add extra requirements – alloy content, toughness or hydrogen level. Example: E8018-B2 H4R = 80 ksi, all positions, basic iron-powder coating, chromium-molybdenum alloy (B2), very low hydrogen (H4) and moisture-resistant coating (R).
| Suffix | Meaning | Example |
|---|---|---|
| -1 | Improved toughness – impact tested at a lower temperature (−46 °C for E7018-1) | E7018-1 |
| A1 | Carbon-molybdenum (about 0.5% Mo) – for higher-temperature service | E7018-A1 |
| B1 – B9 | Chromium-molybdenum steels for boilers, pipes and high-temperature plant (B2 ≈ 1¼Cr-½Mo, B3 ≈ 2¼Cr-1Mo) | E8018-B2, E9018-B3 |
| C1 – C3 | Nickel steels for low-temperature toughness (C1 ≈ 2.5% Ni, C3 ≈ 1% Ni) | E8018-C1, E8018-C3 |
| D1 – D3 | Manganese-molybdenum steels | E9018-D1 |
| P1 | Cellulosic pipeline electrode for high-strength line pipe | E8010-P1 |
| W | Weathering steels – copper, nickel and chromium for corrosion resistance | E8018-W2 |
| M | Military-type specification with tight strength and toughness limits | E11018-M |
| G | General – meets the strength class; alloy content agreed between buyer and maker | E8018-G, E10018-G |
| H4 / H8 / H16 | Diffusible hydrogen limit – max 4, 8 or 16 mL per 100 g of weld metal | E7018 H4 |
| R | Moisture-resistant coating – passes a moisture absorption test | E7018 H4R |
Low-alloy grades such as E7018-1, E8018-G to E10018-G are available from us on order – see Made to Order. Always check the full requirements in the latest AWS A5.1 / A5.5 standards.
Which Electrode Should I Use?
Answer five quick questions and we'll suggest an electrode and size. For critical or code work, always follow your approved welding procedure.
A guide only. Not sure? WhatsApp us your job details and our team will advise.
Stick Welding in 8 Steps
Remove rust, paint, oil and moisture. Bevel plates over about 6 mm.
Pick grade and size for the steel, thickness and position.
Use the packet range – lower for vertical and overhead.
On clean metal, close to the weld.
Scratch like a match or tap lightly, then lift to the arc length.
Arc length about the core diameter. Electrode 70–80° to the work.
Keep an even speed so the bead is uniform and fuses both edges.
Fill the crater before breaking the arc. Chip and brush the slag.
Keep Electrodes Dry
| Type | Re-drying | Holding |
|---|---|---|
| Rutile – E6013 | 100–150 °C, 1 h (only if damp) | – |
| Low hydrogen – E7016, E7018 | 300–350 °C, 1 h | 100–150 °C |
| Cellulosic – E6010, E6011 | Do not re-dry | Store sealed |
Storage Rules
- Keep packets sealed until use, off the floor, below 60% humidity
- Use the oldest stock first
- Never use electrodes with cracked or damp coating
- Return unused low-hydrogen electrodes to the oven
Common Defects & Fixes
| Problem | Likely cause | Fix |
|---|---|---|
| Porosity (holes) | Damp electrodes, rust/oil/paint, long arc, wind | Re-dry electrodes, clean the joint, keep a short arc, shield from wind |
| Undercut | Current too high, wrong angle, travelling too fast | Lower current, pause at the edges, correct electrode angle |
| Excess spatter | Current too high, long arc, damp electrodes, arc blow | Reduce current, shorten arc, use dry electrodes |
| Lack of fusion | Current too low, travelling too fast, poor joint prep | Increase current, slow down, open up the joint gap and bevel |
| Slag inclusions | Slag not removed between passes, low current | Chip and brush every pass, slightly higher current |
| Cracking | Hydrogen from damp electrodes, high-carbon steel, fast cooling | Use low-hydrogen electrodes re-dried, preheat thick or high-carbon steel |
| Electrode sticking | Current too low, poor strike technique | Raise current, use a quick scratch or tap strike |
| Arc blow (wandering arc) | Magnetic effects on DC near the earth clamp or ends | Move the earth clamp, angle the electrode, or switch to AC |
Welding Safety Guide
Electric shock, fumes, arc rays, fire, PPE and first aid – download the full guide.
Questions Welders Ask
What is the difference between E6013 and E7018?
E6013 is a rutile, general-purpose electrode that is easy to use on mild steel. E7018 is a low-hydrogen, iron-powder electrode with higher strength and crack resistance for structural and critical work. E7018 must be kept dry and re-dried before use.
Can I use E7018 on an AC transformer?
Yes, if the machine has an open-circuit voltage of about 70 V or more. On low-OCV transformers, E7016 or E6013 will strike and run more easily.
How much current should I use?
A simple rule is about 30–40 A per mm of electrode diameter, then adjust within the range on the packet. Use the lower end for vertical and overhead welding. Try the calculator above.
Why do my welds have small holes?
That is porosity – usually from damp electrodes, a dirty joint or too long an arc. Re-dry low-hydrogen electrodes, clean rust and paint off the joint and keep the arc short.
Do I need to re-dry E6013?
Only if the electrodes have become damp. Re-dry at 100–150 °C for 1 hour. Do not over-bake rutile electrodes.
What does "low hydrogen" mean?
The coating is designed to put very little hydrogen into the weld. Hydrogen can cause cracking in thick or high-strength steel, so low-hydrogen electrodes like E7016 and E7018 are used for structural and pressure work.
Which size electrode should I choose?
Match the size to the plate: about 2.5 mm for thin sections up to 4 mm, 3.15 mm for 4–8 mm, 4.0 mm for 8–12 mm and 5.0 mm for thicker plate in the flat position. Use smaller sizes for vertical and overhead work.
Still Have a Question?
Our technical team will help you choose the right electrode and settings.